Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 37
Filter
1.
Odovtos (En línea) ; 23(2)ago. 2021.
Article in English | LILACS, SaludCR | ID: biblio-1386539

ABSTRACT

ABSTRACT: The purpose of this study was to evaluate and compare the effect of carbonated beverage on the surface microhardness of two acrylic materials used to fabricate temporary restorations. The study was experimental in vitro. Forty blocks of acrylic resins used in provisional restorations were made, 20 from Alike® (GC AMERICA INC., Lot 1712161) and 20 from Acryptemp® (Zhermack S.P.A., Lot 302334). After that, the blocks were immersed in distilled water for 24 hours. After this time, the initial surface microhardness was measured. Then the 20 samples of the experimental group were immersed in a carbonated drink (coca cola - soda) for 12 minutes per day, for 5 days. Finally, the final surface microhardness was measured using the Vickers microdurometer. Measures of central tendency and dispersion were used, and the Student's t test and ANOVA were performed. A mean surface microhardness of 8.8 and 7.2HV was found for the PMMA resin group (Initial and final respectively), and 9.5 and 8HV for the bisacrylate group. Statistically significant differences were found when comparing the beginning and end of each group and when comparing the two materials. The acrylic resin of polymethylmethacrylate (Alike® GC AMERICA INC.) Presented higher surface microhardness compared to the bis acrylic resin (Acrytemp® Zhermack S.P.A), after being exposed to a carbonated drink.


RESUMEN: El propósito de este estudio fue evaluar y comparar el efecto de la bebida carbonatada en la microdureza superficial de dos materiales acrílicos utilizados para confeccionar restauraciones provisionales. El estudio fue experimental in vitro. Se confeccionaron 40 bloques de resinas acrílicas utilizadas en provisorios, 20 de Alike® (GC AMERICA INC., Lote 1712161) y 20 de Acryptemp® (Zhermack S.P.A., Lote 302334). Posterior a ello, se sumergió los bloques en agua destilada por 24 horas. Pasado este tiempo se procedió a medir la microdureza superficial inicial. Luego las 20 muestras del grupo experimental se sumergieron en una bebida carbonatada (coca cola-gaseosa) durante 12 minutos por día, durante 5 días. Por último se midió la microdureza superficial final mediante el microdurómetro de Vickers. Se utilizaron medidas de tendencia central, dispersión y se realizaron la prueba t de Student y ANOVA. Se encontró una microdureza superficial media de 8,8 y 7,2HV para el grupo de resina PMMA (Inicial y final respectivamente), y 9,5 y 8HV para el grupo de bisacrilato. Se halló diferencias estadísticamente significativas al comparar el inicio y final de cada grupo y al comparar los dos materiales. La resina acrílica de polimetilmetacrilato (Alike® GC AMERICA INC.) presentó mayor microdureza superficial en comparación con la resina bis acrílica (Acrytemp® Zhermack S.P.A), después de ser expuestas a una bebida carbonatada.


Subject(s)
Acrylic Resins/analysis , Carbonated Beverages/adverse effects , Peru , Hardness
2.
Arq. ciênc. vet. zool. UNIPAR ; 19(2): 101-105, abr.-jun. 2016. ilus
Article in Portuguese | LILACS, VETINDEX | ID: biblio-833078

ABSTRACT

A fenda palatina é uma comunicação congênita ou adquirida entre as cavidades oral e nasal, permitindo a passagem de alimentos e líquidos entre elas. O diagnóstico é feito por meio do exame físico da cavidade oral, sendo o tratamento baseado em técnicas cirúrgicas. Relata-se um caso bem-sucedido de oclusão de fístula oronasal utilizando somente resina acrílica autopolimerizável em um felino com histórico de espirros frequentes, secreção nasal purulenta crônica, halitose severa, emagrecimento e trauma sofrido há dois anos, que culminara em fratura da sínfise mandibular corrigida no mesmo período por cerclagem com fios de aço. No exame clínico verificou-se secreção nasal muco-purulenta fétida e a presença de uma grande fístula palatina na extensão do palato duro. Encaminhou-se o paciente para realização dos exames pré-cirúrgicos para posterior correção da fistula oronasal com o uso de resina acrílica autopolimerizavel. O procedimento foi bem sucedido visto que o animal deixou de apresentar os sinais clínicos e voltou a alimentar-se normalmente. A técnica mostrou-se eficaz e de fácil execução para correção de fenda palatina traumática de grande extensão em gato, na qual não se utilizou suturas ou flaps, pois os mesmos não eram praticáveis, podendo ser utilizada em substituição a outros métodos convencionais.


Cleft palate is a congenital or acquired communication between the oral and nasal cavities which can often contaminate the nasal cavity with saliva or food. The diagnosis is made by physical examination of the oral cavity and it is usually treated with surgery. We report a successful case of oronasal fistula occlusion using only acrylic resin in a feline. The patient presented with a history of frequent sneezing, chronic purulent nasal discharge, severe halitosis, weight loss and facial trauma suffered two years ago. The animal had mandibular symphysis fracture that was corrected by cerclage with steel wires. On clinical examinationit was observedthe presence of smelling nasal mucus, purulent secretions and the presence of a large cleft fistula in the extension of the hard palate. The patient was submitted to surgery in order to repair the oronasal fistula using acrylic resin. The surgery was curative eliminating clinical signs. The technique was effective and easy to be performed in this case of a traumatic cleft palate with large deffect in a cat. This technique can be used to replace other conventional methods, mainly in cases that the use of sutures or flaps are not feasible.


El paladar hendido es una comunicación congénita o adquirida entre las cavidades oral y nasal, lo que permite el paso de alimentos y líquidos entre ellos. El diagnóstico se realiza mediante un examen físico de la cavidad oral, siendo el tratamiento basado en técnicas quirúrgicas. Presentamos un caso de éxito de oclusión de la fístula oronasal usando sólo la resina acrílica autopolimerizável en un felino con histórico de frecuentes estornudos, secreción nasal purulenta crónica, halitosis severa, pérdida de peso y trauma sufrido hace dos años, culminando en fractura de la sínfisis mandibular, corregida en el mismo período por cerclaje con hilos de acero. En el examen clínico se verificó moco nasal maloliente, secreciones purulentas y la presencia de una gran fístula palatina en la extensión del paladar duro. Se hicieron exámenes pre-quirúrgicos para la posterior corrección de la fístula oronasal, mediante resina acrílica autopolimerizavel. El procedimiento fue exitoso porque el animal dejó de presentar signos clínicos y volvió a alimentarse normalmente. La técnica fue eficaz y de fácil ejecución para corrección de paladar hendido traumático de gran longitud en gato, en la cual no se utilizó suturas o aletas, ya que no eran viables y puede ser utilizado para sustituir a otros métodos convencionales.


Subject(s)
Animals , Cats , Cleft Palate/veterinary , Fistula/diagnosis , Acrylic Resins/analysis
3.
Arq. odontol ; 49(1): 6-11, 2013. ilus
Article in English | LILACS, BBO | ID: lil-698338

ABSTRACT

Aim: Evaluate the performance of four commercially available chemically-activated acrylic resins (CAARs) by measuring the level of displacement of the cores following casting. Materials and Methods: Two devices were constructed to model the cores based on a natural tooth. Forty post/cores were modeled, 10 in each of the following CAARs: Duralay (Reliance Dental, Illinois, USA), Pattern Resin (GC, Tokyo, Japan), Dencrilay (Dencril, Sao Paulo, Brazil), and Jet (Clássico, Sao Paulo, Brazil). Two casting rings were included, each of which contained 5 post/cores for each of the four CAARs tested, a total of 20 per ring. Following casting, the specimens were only sandblasted and separated from the feeding channels. The post/cores were placed in device 1 and, with the aid of an optical microscope, were attached to a digital camera. Images were then taken of the adjustment between the core and the remaining tooth on the labial surface. The images were processed using the Image Tool for Windows, version 3.0, measuring three fixed points in each specimen. Data were statistically analyzed using the ANOVA and Tukey test. Results: The 40 post/cores were divided into eight groups according to resin brand and casting, obtaining the following results for mean and standard deviation (in mm): Dencrilay 0.192 CI (± 0.08), CII 0.058 (± 0.03); Duralay CI 0.097 (± 0.03), CII 0.131 (± 0.06); Pattern CI 0.07 (± 0.03), CII 0.10 (± 0.05); and Jet CI 0.06 (± 0.02), CII 0.382 (± 0.17). Statistically significant differences could be identified when comparing the Dencrilay CI and the Jet CII with the remaining groups, which all proved to be unfavorable. Conclusion: The quality of cast metal post/core adjustment is not associated with the use of a specific acrylic resin.


Subject(s)
Acrylic Resins/analysis , Post and Core Technique/trends , /statistics & numerical data , Dental Pins/statistics & numerical data
4.
Arq. odontol ; 45(4): 178-183, 2009. ilus
Article in Portuguese | LILACS, BBO | ID: lil-578244

ABSTRACT

Este trabalho analisou, pelo método dos elementos finitos tridimensional (MEF 3D), as tensões geradas, na interface entre a resina acrílica e a infra-estrutura metálica, quando são aplicadas cargas funcionais na região de extremo distal livre, em uma prótese total inferior, implantossuportada. Foi desenvolvido um MEF 3D de uma prótese total implantossuportada, inferior, tipo protocolo de Branemark, com 12 mm de cantilever bilateral. O pacote do programa SolidWorks® foi utilizado no pré e pós processamento dos dados. Na primeira simulação, o carregamento foi aplicado na superfície oclusal do primeiro pré-molar, na segunda, no primeiro e no segundo pré-molares e, na terceira, no primeiro e segundo pré-molares e no primeiro molar. Os resultados obtidos puderam ser visualizados tridimensionalmente, por imagens, com escalas e gráficos, mostrando que o padrão de oclusão na região da extremidade distal livre gerou uma distribuição das tensões uniforme nas três simulações, com os maiores níveis de tensão localizados na região do primeiro implante, em todos os casos. Porém, conforme os carregamentos foram se deslocando para distal, as tensões aumentavam consideravelmente. Foi possível concluir que quanto mais extensa a extremidade distal livre, mais comprometida será a interface entre a resina acrílica e a infra-estrutura metálica, e independentemente do comprimento do extremo livre distal, as maiores tensões sempre se localizam na interface entre a resina acrílica e a infraestrutura metálica ao redor da região do implante localizado mais próximo à extremidade distal livre, do lado de trabalho.


Subject(s)
Humans , Male , Female , Dental Prosthesis, Implant-Supported , Denture, Complete, Lower , Acrylic Resins/analysis , Finite Element Analysis , Biomechanical Phenomena , Dental Occlusion
5.
Rev. bras. eng. biomed ; 24(1): 17-22, abr. 2008. ilus, graf
Article in English | LILACS | ID: lil-510116

ABSTRACT

Este trabalho tem por finalidade avaliar a resistência abrasiva de 3 diferentes marcas de cimento de ionômero de vidro (CIV) restauradores, do tipo convencional, disponíveis no mercado nacional. Para isso foi utilizado o teste de agressividade, onde um disco dinâmico revestido com porcelana desgasta, em condições adequadamente estabelecidas, um disco estático revestido com o material restaurador estudado. Neste método valores menones de agressividade indicam maior resistência ao desgaste abrasivo. Foram confeccionados 24 corpos de provas, sendo 8 para cada marca. As marcas de CIV avaliadas foram: Vidrion R (fabricado pela empresa brasileira SSWhite), Ketac Fil Plus (fabricado pela empresa americana 3M ESPE) e Fuji IX GP (fabricado pela empresa japonesa GC), que posteriormente foi substituído pela marca Vitro Fill (fabricado pela empresa brasileira DFL Indústria e Comércio Ltda.). Os materiais foram confeccionados de acordo com as instruções dos respectivosfabricantes. Os testes foram executados em duas etapas: na primeira não houve controle do tempo de exposição ao ambiente, e as análises dos dados revelaram grande influência desta exposição na propriedade de resistência ao desgaste abrasivo. Em uma segunda etapa, o tempo de exposição foi rigidamente controlado, assim como a umidade do ar e a temperatura ambiente, desde a confecçãodos corpos de prova até a finalização dos ensaios, otendo-se assim os resultados desejados. Deste modo, além da classificação de cada marca de acordo com a resistência ao desgaste abrasivo, também foi mostrado que o tempo de exposição deste material ao ar ambiente deve receber atenção especial em trabalhos que versem sobre propriedades mecânicas do cimento de ionômero de vidro.


An evaluation was made of the abrasive strenght of three different brands of conventional glass ionomer cement (GIC) for dental restoration available on the Brazilian market. The evaluation was based on an agressiveness assay in which, under pre established conditions, a disk coated with porcelain wears down a static disk coated with the restorative material under study. According to this method, low agressiveness values indicate high abrasive wear resistance...


Subject(s)
Tooth Abrasion/chemically induced , Glass Ionomer Cements/analysis , Dental Cements , Dental Materials/analysis , Acrylic Resins/analysis
6.
Braz. j. oral sci ; 6(23): 1442-1444, Oct.-Dec. 2007. tab
Article in English | LILACS, BBO | ID: lil-518090

ABSTRACT

Previous studies have investigated the possible influences to different types of polymerization and polishing procedures in some properties of acrylic resins. Water sorption is an important property, which may be induced by these factors. The aim of this work was to evaluate water sorption in acrylic resin processed in microwave energy or water bath, after chemical and mechanical polishing. Forty heatpolymerized acrylic resin (Vipi-Cril, Dental VIPI Ltd, Pirassununga, São Paulo, Brazil) specimens were made according to ADA Specification No.12 for Denture Base Polymers and divided into 4 groups: Groups I and II were processed in microwave energy (500 W for 3 minutes); Groups III and IV, in water bath (73ºC ± 1ºC for 9 hours). Groups I and III were polished chemically; Groups II and IV were polished mecahnically. The specimens were submitted to water sorption test. The water sorption values (mg/cm2) were calculated and submitted to ANOVA and Tukeyïs test (5% significance level). The obtained results were: Group I: 0.000953, Group II: 0.001069, Group III: 0.000958 and Group IV: 0.001491. No statistical difference were found among the groups (p>.05). Polymerization by microwave energy or water bath associated with chemical or mechanical polishing did not influence the water sorption of the heat polymerized acrylic resin evaluated.


Subject(s)
Acrylic Resins , Microwaves , Acrylic Resins/analysis , Absorption , Water
7.
Rev. ABO nac ; 14(4): 242-247, ago.-set. 2006. tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-544739

ABSTRACT

Introdução - Há muito se apresentam tentativas para estabelecer padrões de resinas e técnicas de processamento ideais para obtenção de bases protéticas; com os resultados biológicos positivos dos implantes osseointegrados e, mais recente ainda, com a execução de trabalhos protéticos realizados imediatamente, algo em torno de 12 ou 24 horas pós-cirúrgico, uma variável tornou-se importante, que é o tempo de trabalho laboratorial. Este trabalho avaliou comparativamente as características físicas, estabilidade dimensional e absorção de água, de resinas acrílica, consideradas de polimerização rápida, utilizadas para bases de próteses implanto-retidas e implanto-suportadas, em função imediata, quais sejam: uma fotopolimerizável (Vercyo.com), uma ativada através de microondas (Acrom - MC), uma termopolimerizável em água (Impact - Bosworth) e outra termopolimerizável (Lucitone 199), pelo método convencional (grupo controle). Materiais e Método - O manuseamento dos materiais se realizou de acordo com as orientações dos fabricantes. Foram confeccionados 10 corpos de prova de cada resina acrílica, em cinco matrizes metálicas (discos), com dimensões de 25x10x2 mm e um orifício central de 10 mm de diâmetro e os resultados foram analisados, estatisticamente, através do Teste de Análise de Variância a um critério e o Teste de Tukey, para comparação entre as médias. Resultados - Os resultados mostraram que as resinas apresentaram diferenças, estatisticamente significante, tanto para o teste de absorção de água quanto para estabilidade dimensional linear. Conclusão - A resina do Grupo B apresentou as características físicas avaliadas, com diferenças estatísticas significantes em relação às outras resinas.


Introduction - Several attempts have been made to establish patterns of ideal resins and processing techniques, for achievement of prosthetic bases. With the positive biological outcomes of osseointegrated implants and, more recently, with the accomplishment of immediate prosthetic rehabilitations, at 12 to 24 hours postoperatively, a variable has become important, which is the laboratory time. This study comparatively evaluated the physical characteristics, dimensional stability and water absorption of fast-curing acrylic resins employed for fabrication of implant-retained and implant-supported prosthetic bases with immediate function, as follows: one light-cured (Vercyo.com), one microwave-cured (Acrom - MC), one heat-cured in water (Impact - Bosworth) and one heat-cured (Lucitone 199), by the conventional method (control group). Materials and Method - Handling of the materials followed the manufacturers' instructions. Ten specimens were fabricated from each acrylic resin, in five metallic templates (discs), with dimensions of 25x10x2 mm and a central orifice with 10 mm diameter; results were statistically analyzed by one-way analysis of variance and the Tukey Test, for comparison between the means. Results - The results demonstrated that the resins presented statistically significant differences for both water absorption and dimensional linear stability. Conclusion - The resin in Group B presented the physical characteristics evaluated, with statistically significant differences compared to the other resins.


Subject(s)
Dental Prosthesis , Dental Implants , Materials Testing , Polymers , Acrylic Resins/analysis
8.
J. Health Sci. Inst ; 20(1): 45-50, jan.-jun. 2002. ilus, tab
Article in Portuguese | LILACS | ID: lil-324041

ABSTRACT

Este trabalho comparou o efeito da termociclagem sobre a resistencia à traçäo da uniäo de dois materiais reembasadores resilientes utilizados com a base de resina acrílica da prótese total, sendo um composto de silicone (Molloplast-B) e um composto de resina acrílica (Eversoft). AS resinas acrílicas selecionadas foram a Clássico e a Lucitone 199. Foram utilizadas 80 amostras divididas em 8 grupos. Para confecçäo das amostras foram utilizadas matrizes metálicas incluídas em mufla, cujo molde impresso no solicone de condensaçäo e no gesso foi preenchido com resina acrílica e/ou material resistente. Em seguida, metade das amostras foi levada ao termociclador MCT2 AMM Instrumental onde foram realizados 3.000 ciclos de 1 minuto em água a 5 graus celsius e 1 minuto em água a 55 graus celsius. A outra metade das amostras foi armazenada em água a 37 graus celsius durante 24 horas. As amostras foram submetidas a tracionamento no equipamento EMIC DL-500 MF com velocidade de 5 mm/minuto. Todos os dados obtidos foram submetidos à análise de variância, as médias comparadas pelo teste de Tukey em nível de 5 porcento de probalidade e as amostras foram analisadas quanto ao tipo de ruptura ocorrida. Independentemente do tratamento recebido e resina acrílica utilizada, o material Molloplast-B apresentou os maiores valores e o material Eversoft, os menores. A termociclagem diminuiu todos os valores ecausou diferença estatística apenas para o material Molloplast-B. O tipo de resina acrílica utilizada independente do material e tratamento realizados näo gerou diferença estatística.(au)


Subject(s)
Dental Materials , Denture Liners , Denture, Complete , Acrylic Resins/analysis
9.
Rev. bras. odontol ; 59(2): 90-93, mar.-abr. 2002.
Article in Portuguese | LILACS, BBO | ID: lil-312607

ABSTRACT

As restauraçöes provisórias devem proporcionar proteçäo pulpar, resistência à abrasäo, lisura superficial, margens bem delimitadas, resistência, retençäo e estética. Entretanto, näo existe material capaz de preencher completamente esses requisitos, levando o cirurgiäo-dentista a ponderar sobre as vantagens e desvantagens de cada material ao fazer a seleçäo. A proposta de presente trabalho foi fornecer informaçöes aos profissionais da área de Odontologia sobre os materiais resinosos utilizados na confecçäo de restauraçöes provisórias. A ausência de uma resina que preencha todas as características de um material provisório "ideal", torna a seleção um processo que envolve inúmeros fatores


Subject(s)
Composite Resins , Materials Testing , Acrylic Resins/analysis , Dental Restoration, Temporary/standards
10.
Rev. bras. odontol ; 59(2): 128-132, mar.-abr. 2002. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-312617

ABSTRACT

O presente trabalho consiste em uma análise de tensöes por elementos finitos de implantes osseointegrados com diferentes materiais da coroa protética. Foram comparadas próteses sobre implantes mediante variaçäo do material da coroa protética. Uma análise comparativa entre porcelana, resina compósito Charisma, resina compósito Artglass e resina acrílica Biotone foi realizada. Constatou-se que a coroa de porcelana absorve as menores tensöes, porém transmite para a regiäo inferior do pilar intermediário, próxima ao osso cortical de suporte as maiores tensöes quando comparada com as coroas de resina compósito Charisma, resina compósito Artglass e resina acrílica Biotone


Subject(s)
Finite Element Analysis , Composite Resins , Crowns , Materials Testing , Osseointegration , Dental Porcelain/analysis , Dental Prosthesis, Implant-Supported/methods , Acrylic Resins/analysis
11.
Ciênc. rural ; 31(2): 291-298, mar.-abr. 2001. ilus
Article in Portuguese | LILACS | ID: lil-301450

ABSTRACT

O trabalho foi desenvolvido em duas fases. A primeira constou de aplicaçäo de resina acrílica autopolimerizável sobre dentes de cäes experimentais, sem condicionamento ácido do esmalte dental; a gengiva foi analisada histologicamente nos períodos de um, três, sete, 14, 21 e 30 dias. A segunda fase foi conduzida em 20 cäes e 10 gatos com fraturas do sistema estomatognático, atendidos no Ambulatório Central da FMVZ/USP. Nessa segunda fase, clínica, foi aplicado condicionamento ácido do esmalte. A resina era usada nas fraturas rostrais às raízes distais do primeiro molar inferior e do quarto pré-molar superior, bem como na separaçäo da sínfise mentoniana. Os resultados da primeira fase mostraram que mesmo sem o condicionamento ácido houve aderência da resina acrílica sobre os dentes, embora houvesse necessidade de maior volume do material, o que provocou ulceraçöes dos tecidos moles da boca. Essa fase também evidenciou, à sondagem, que o epitélio de aderência sulcular permaneceu aderido, além de gengivite, ulceraçäo da gengiva, língua e mucosa alveolar. A análise histológica revelou predominantemente ulceraçäo dos tecidos em contato com a resina. Na segunda fase, todos os animais evidenciaram consolidaçäo óssea das fraturas, além de gengivite e ulceraçäo. Lesöes periodontais foram encontradas em dois animais dos quais a resina foi removida tardiamente, com quatro e 12 meses após a aplicaçäo, respectivamente. Em ambas as fases, os animais adaptaram-se bem à resina sobre os dentes.


Subject(s)
Animals , Dogs/injuries , Cats , Mandibular Fractures , Maxilla , Acrylic Resins/analysis , Acrylic Resins/toxicity
12.
Pesqui. odontol. bras ; 14(3): 278-82, jul.-set. 2000. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-271817

ABSTRACT

A proposta deste estudo foi comparar as alteraçöes dimensionais de 3 resinas submetidas à polimerizaçäo com os seguintes ciclos: 1) banho d'água em 73ºC durante 12 horas-ciclo longo, 2) banho d'água durante 3 horas-ciclo curto, 3) energia de microondas por 3 minutos a potência de 500 W, após armazenamento em água destilada a 37 ñ 2ºC durante 30 dias. As resinas usadas foram Clássico, Lucitone 550 e Acron MC. As resinas Clássico e Lucitone 550 foram submetidas aos três, enquanto a resina Acron-MC somente ao ciclo 3. Amostras medindo 65,0 x 10,0 x 3,0 mm e com marcas iguais em três pontos eqüidistantes foram confeccionadas a partir da inclusäo de matrizes de aço em gesso-pedra tipo III. Foram confeccionados 21 corpos-de-prova para cada combinaçäo resina/ciclo de polimerizaçäo e que foram submetidos a 3 leituras para cada posiçäo (A e B), com auxílio do microscópio de mensuraçäo (precisäo de 0,001 mm), imediatamente após a polimerizaçäo e depois do período de imersäo em água por 30 dias. Os resultados mostraram que todas as resinas, independendo do ciclo a que tenham sido submetidas e das medidas avaliadas, apresentaram expansäo dimensional após terem sido mantidas em água; a composiçäo da resina interferiu na expansäo dimensional mais do que o ciclo de polimerizaçäo ao qual as resinas foram submetidas; a resina convensional, quando polimerizada com energia de microondas, apresentou alteraçäo dimensional semelhante à resina desenvolvida para a polimerizaçäo em micrrondas


Subject(s)
Polymers , Acrylic Resins/analysis , Microwaves
13.
Rio de Janeiro; s.n; 2000. 101 p. ilus, tab. (BR).
Thesis in Portuguese | LILACS, BBO | ID: lil-296623

ABSTRACT

O ajuste cervical das restauraçöes fixas é o principal fator de substituiçäo deste tipo de prótese dentária. Várias säo as causas que podem determinar estes desajustes. Entre estas, dependendo da sua magnitude, podemos citar as rugosidades superficiais. O objetivo desta pesquisa foi avaliar a influência dos revestimentos fosfatados Microfine 1700 (R1) e Termocast (R2), às ligas de níquel-crômio Verabond (L1) e Durabond (L2), submetidas as temperaturas normais e de 100ºC acima da normalidade para estufagem de anéis e fusäo das ligas, na rugosidade superficial. Foram utilizados 80 corpos de prova de acrílico que foram divididos em 16 grupos, em funçäo das variáveis, com 5 repetiçöes cada. Os corpos de prova foram fundidos em centrífuga, por induçäo. Para proceder à leitura da rugosidade, foi utilizado o rugosímetro DENTAK II. Foram realizadas cinco leituras em cada superfície externa e interna dos corpos de prova, perfazendo 800 leituras. Os principais resultados indicam que as variáveis utilizadas determinam graus variáveis de rugosidade superficial. As superfícies externas e internas comportaram-se de forma semelhante. A melhor combinaçäo do revestimento/liga foi a do revestimento Microfine 1700 (R1) associado à liga Durabond (L2). As rugosidades encontradas, possivelmente näo determinariam desajustes cervicais de restauraçöes metálicas fundidas


Subject(s)
Chromium Alloys/analysis , Dental Casting Technique , Inlay Casting Wax/analysis , Inlay Casting Wax/classification , Inlay Casting Wax/therapeutic use , Acrylic Resins/analysis , Acrylic Resins/therapeutic use , Dental Casting Investment/analysis , Inlays
14.
Säo Paulo; s.n; 2000. 81 p. ilus, tab. (BR).
Thesis in Portuguese | LILACS, BBO | ID: lil-283656

ABSTRACT

Determinaram-se os parâmetros de cor em corpos-de-prova de resina acrílica, circulares, com espessuras de 6, 4 e 2mm. As resinas ensaiadas foram: cor rosa médio (Clássico e Vipi); cor 66 Dencor (Clássico), Vipi-cor (Vipi) e Duralay (Reliance). As quantidades de pó variaram para uma mesma de líquido sendo (por cento): +10, normal, -10 e -20. As diferenças de cor foram calculadas com base nas comparaçöes: 1) proporçöes em relaçäo à de +10 por cento; 2) espessura de 4 e 2mm em relaçäo à de 6mm; 3) comparaçäo entre as duas resinas de cor rosa médio e entre as três de cor 66. Os resultados permitiram concluir que: a variaçäo na proporçäo pó/líquido representou pouca influência na diferença de cor; na maior espessura ocorreu a maior diferença de cor, o mesmo aconteceu na espessura de 2mm quando em relaçäo à de 6mm; no entanto, a de 4mm forneceu valores de AE pequenos; os valores analisados sugerem semelhança na observaçäo visual entre as resinas de cor rosa médio, mas entre as de cor 66, a discrepância foi muito grande; na comparaçäo de materiais com opacidade semelhante, encontrou-se menos influência da espessura


Subject(s)
Acrylic Resins/analysis , Color
15.
RPG rev. pos-grad ; 6(3): 245-8, jul.-set. 1999. tab
Article in Portuguese | LILACS, BBO | ID: lil-271553

ABSTRACT

O objetivo da pesquisa foi determinar a resistência transversal de resinas acrílicas para base de dentaduras ativadas química (RAAQ) e termicamente (RAAT). A polimerizaçäo da RAAQ foi feita com ativaçäo química apenas ou adicionalmente com térmica (1,5 h/70ºC + 1,0 h/100ºC). A polimerizaçäo da RAAT, por sua vez, foi realizada pelos métodos: usual (1,5 h/70ºC + 1,0 h/100ºC), com microondas e com luz de lâmpada halógena. Ainda, empregou-se uma resina de ativaçäo térmica especial, com um ciclo rápido (levar o banho até 100ºC, desligar a fonte de calor por 20 minutos, reaquecer até 100ºC e manter por 20 minutos). As conclusöes foram: a resistência transversal da RAAQ näo foi influenciada pelo método de polimerizaçäo; a resistência da RAAT tradicional também näo foi; o ciclo rápido conduziu a uma resistência muito baixa em relaçäo aos demais tipos, que näo foram significantes entre si


Subject(s)
Materials Testing , Acrylic Resins/analysis , Denture Bases , Denture, Complete
16.
RPG rev. pos-grad ; 6(1): 55-9, jan.-mar. 1999. tab
Article in Portuguese | LILACS, BBO | ID: lil-250676

ABSTRACT

A investigaçäo teve o objetivo de determinar as forças de retençäo de grampos a barra tipo "I" de Roach. Usaram-se duas ligas à base de cobalto-cromo, quatro dimensöes distintas de grampos (curto-grosso, curto-fino, longo-grosso e longo-fino), com a resina acrílica da sela cobrindo ou näo parte do braço retentivo. As medidas de retençäo foram realizadas no início (ciclo zero) e após subseqüentes ciclagens (x10ü: 1, 2, 5, 10 e 20) de inserçäo e remoçäo dos grampos em uma matriz metálica. Os resultados permitiram concluir que: a liga Wironit apresentou maior força de retençäo do que a Vera PDI; a presença de resina da sela aumentou a média da retentividade em 52,7 por cento; os grampos curtos-grossos foram os mais retentivos, e os longo-finos, os menos; a força de retençäo média diminuiu mais acentuadamente até os 1.000 ciclos (21,7 por cento) e gradativamente menos até o final da ciclagem


Subject(s)
Dental Clasps , Dental Prosthesis Retention/methods , Dental Alloys , Acrylic Resins/analysis
17.
RFO UPF ; 3(2): 7-14, jul.-dez. 1998. ilus
Article in Portuguese | LILACS, BBO | ID: lil-250208

ABSTRACT

O objetivo deste estudo foi verificar a rugosidade superficial produzida pela associaçäo escova dental-dentifrício sobre corpos-de-prova de resina acrílica. A partir de uma matriz metálica com 47x20x2 mm, foram confeccionadas placas de resina acrílica ativada termicamente (Clássico), as quais, em seguida, foram divididas em quatro grupos de acordo com o dentifrício utilizado, ou seja: creme dental Sorriso (Anakol), gel dental Liqui Fresh (Gessy Lever), creme dental experimental (específico para próteses) e água (controle). Cada grupo foi dividido em três subgrupos de acordo com a escova utilizada - Denture (Anakol, específica para próteses), Doctor (Anakol) e Oral-B 30 (Gillete do Brasil), submetidos a trinta mil ciclos de escovaçäo mecânica. Em seguida, foram feitas três leituras da rugosidade em cada corpo-de-prova com um rugosímetro Prazis Rugo3, cujos resultados foram submetidos à análise de variância e ao teste de Tukey, com 5 por cento de significância. O dentifrício experimental (específico para próteses) obteve a maior média de rugosidade, seguido pelos dentifrícios Sorriso Liqui Fresh e água, todos diferentes estatísticamente entre si (p>0,05). Näo houve diferença estatística entre as escovas Denture, Doctor e Oral-B 30 (p>0,05)


Subject(s)
Dental Devices, Home Care , Dental Prosthesis , Dentifrices/analysis , Acrylic Resins/analysis , Tooth Abrasion , Toothbrushing
18.
Rev. odontol. UNESP ; 27(1): 299-309, jan.-jun. 1998. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-250895

ABSTRACT

Neste estudo foram avaliados a resistência a traçäo e o alongamento de duas resinas autopolimerizáveis, indicadas para o reembasamento imediato, e de uma resina termopolimerizável, utilizada tanto na confecçäo de bases de próteses como no reembasamento do tipo mediato. Os testes foram realizados em uma máquina de ensaios mecânicos, após o armazenamento dos corpos-de-prova em água destilada a 37ºC, por 48 horas e 30 dias. Os resultados obtidos foram submetidos a análise de variância, seguida pelo Teste de Duncan a 95 por cento de confiança, indicando que a resina termopolimerizável Lucitone 550 apresentou resistência a traçäo superior às das resinas para reembasamento imediato Duraliner II e Kooliner. Entre os materiais para reembasamento imediato, a resina Duraliner II apresentou maior porcentagem de alongamento, ao passo que a resina termopolimerizável Lucitone 550 proporcionou os menores valores. Além disso, foi possível observar que os dois períodos de armazenagem avaliados näo influenciaram a resistência a traçäo e o alongamento dos materiais analisados


Subject(s)
Acrylic Resins/analysis , Tensile Strength
19.
Rev. odontol. Univ. Säo Paulo ; 12(2): 173-80, abr.-jun. 1998. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-222432

ABSTRACT

Com o objetivo de verificar a efetividade da energia de microondas na polimerizaçäo da resina acrílica próxima ao metal, foram confeccionados 36 corpos-de-prova cilíndricos com 30,0mm de diâmetro X 4,0mm de espessura, contendo no seu interior uma sela metálica com 28,0mm X 8,0mm X 0,5mm, divididos aleatoriamente em 3 grupos e submetidos aos seguintes processamentos: G1) resina Clássico polimerizada em ciclo curto; G2) resina Acron-MC polimerizada em forno de microondas por 3 minutos a 500 W; G3) resina Clássico polimerizada em forno de microondas por 3 minutos a 500 W. Após a polimerizaçäo, cada amostra foi dividida em duas partes aproximadamente iguais, sendo que uma das partes foi utilizada para a avaliaçäo de monômero residual, enquanto a outra foi submetida aos testes de dureza e porosidade. A dosagem de monômero liberada na água durante doze dias consecutivos foi avaliada através da espectrofotometria...


Subject(s)
Microwaves , In Vitro Techniques , Acrylic Resins/analysis , Hardness , Dental Materials , Polymers
20.
Rev. odontol. Univ. Säo Paulo ; 11(3): 189-94, jul.-set. 1997. ilus, tab
Article in English | LILACS, BBO | ID: lil-197541

ABSTRACT

A resistência de uniäo dos adesivos dentinários tem sido aumentada com o desenvolvimento de cada nova geraçäo. Pouca importância tem sido dada à resistência coesiva da dentina. A proposta deste estudo foi avaliar a resistência coesiva da dentina. Dezessete caninos humanos hígidos, os quais tinham sido extraídos há mais de um ano, foram usados. Os dentes foram desgastados até a obtençäo de corpos-de-prova em dentina, de formato quadrangular, com tamanho aproximado de 2 x 2 mm. Os dentes foram incluídos em resina acrílica e, entäo, submetidos ao teste de cisalhamento em uma máquina de ensaios universais Wolpert, com uma velocidade de 0,5 mm/min. A resistência coesiva média da dentina no teste de cisalhamento foi de 33,95 (ñ9,72) MPa. O tipo de fratura foi analisado com um aumento de 40X. Foi realizada uma análise com elemento finito, para observar a distribuiçäo do estresse relacionada com o teste de cisalhamento. O padräo de fratura encontrado foi compatível com o tipo de teste executado e com a distribuiçäo do estresse obtida a partir da análise de elemento finito


Subject(s)
Dentin , Dentin-Bonding Agents/analysis , Acrylic Resins/analysis , Cuspid , Dental Stress Analysis
SELECTION OF CITATIONS
SEARCH DETAIL